GGD AC Low-voltage Power Distribution Cabinet


PRODUCT DETAILED PARAMETERS

Product overview:
GGD type AC low-voltage power distribution cabinet is suitable for power users such as power plants, substations, factories and mining enterprises, applicable to such as AC 50Hz, rated working voltage 380V, rated working current up to 3150A power distribution system, is used for the power conversion distribution and controlof power, lighting and power distribution equipment.
The GGD AC low-voltage power distribution cabinet is a new type of low-voltage power distribution cabinet designed ir accordance with the requirements of the superiors in charge of the Ministry of Energy and the majority of power users and design departments, on the basis of the principles of safety, economy, reasonableness and reliability. The product has the characteristics of high breaking capacity, good dynamic and thermal stability, exible electrical solution, convenient combination, various series,strong practicability, novel structure, high protection level, etc., and can be used as an updated product of low-voltage switchgear.
The GGD AC low-voltage power distribution cabinet complies with IEC439 "L ow-Voltage Switchgear and Control Equipment", GB7251 "Low-Voltage Switchgear" and other standards.
Model and meaning:

①Power cabinet
②Fixed installation and fixed wiring of electrical components
③AC low-voltage power distribution cabinet
1- -The breaking capacity is 15kA
④Design No.
2- -The breaking capacity is 30kA
3- The breaking capacity is 50kA
⑤Main circuit solution code
⑥Auxiliary circuit solution code
Service condition:
◇The ambient air temperature shall not be higher than +40°C , not lower than -5°C , and the average temperature within 24h shall not be higher than +35°C ;
◇ For indoor installation and use, the altitude of the place of use shall not exceed 2000m;
◇The relative humidity of the surrounding air does not exceed 50% when the maximum temperature is +40 °C , and a larger relative temperature should be allowed at a lower temperature (e.g.: 90% at +20 °C ), taking into account the possibility of temperature changes will occasionally cause condensation effects;
◇ When the equipment is installed, the inclination to the vertical plane should not exceed 5° ;
◇The equipment should be installed in a place where there is no severe vibration, impact and corrosion.
◇When the user has special requirements, it can be resolved through consultation with the manufacturer.
Electrical performance
Basic electrical parameters

Main circuit solution
The main circuit of the GGD cabinet has 129 solutions designed with a total of 298 specifications (excludingsolutions and specifications derived from changes in the function of the auxiliary circuit and changes in the control voltage).
Wherein GGD1 type 49 solutions are available of 123 specifications
GGD2 type 53 solutions are available of 107 specifications
GGD3 type 27 solutions are available of 68 specifications
The main circuit solution is selected by soliciting the opinions of the majority of design and user departments, and the solution required by the power plant has been added. The rated current is up to 3150A, suitable for the selection of distribution transformers of 2000kVA and below. In addition, GGJ1 and GGJ2 capacitor compensation cabinets are designed to meet the needs of reactive power compensation, with 4 main circuit solutions and 12 specifications in total.
Auxiliary circuit solution
The design of the auxiliary circuit is available of two parts solutions: the power supply plan and the power generation plant. There is enough space in the GGD cabinet to install the secondary components. At the same time, a special LMZ3D current transformer has been developed to meet the needs of power plants and special userswhen the attached relay protection is necessary.
Main bus
Considering the price ratio and the feasibility of replacing copper with aluminum, single aluminum buss can be used when the rated current is 1500A and below, and double copper buss are used when the rated current is greater than 1 500A. The manufacturer will produce prototypes and do "pass” the type test according to this regulation. Of course, the manufacturer can also replace the aluminum bus with a copper bus of the same current carrying capacity as the users requires. The overlapping surfaces of the buss are all treated with tin enamelling process.
Selection of electrical components
(1).GGD cabinet mainly uses the electrical components produced. it also retains some features of old products such as DZ10D,DZ20, etc. under the premise of fully considering the feasibility according to economic and reasonable principles. Obsolete products are not used any more.
(2) HD13BX and HS13BX rotary operation knife switch is a special component designed to meet the needs of the unique structure of the GGD cabinet. It changes the operation mode of the mechanism and retains the advantages of the old product. It is a practical new type of electrical components.
(3). If the design department chooses new electrical components with better performance according to the needs of users, because the GGD cabinet has good installation exibility, it will generally not cause manufacturing and installation difficulties due to the updated electrical components.
(4) In order to further improve the dynamic stability of the main circuit, a ZMJ type combined bus clamp and insulating support for the GGD cabinet are designed. The bus clamp is made of high-strength, high ame-retardant PPO alloy material, with high insulation strength, good self-extinguishing performance, and unique structure. It can be easily combined into a single bus clamp or a double bus clamp by adjusting the building block. The insulating support is a sleeve-type molded structure with low cost and high strength, which solves the defect of insufficient creepage distance of old products.
Shape and installation dimensions


Complete set of products
Our company provides the following documents and attachments when supplying:
◇Packing List
◇Product certification
◇User's manual
◇Factory test report
◇ Related electrical drawings
◇Keys for Cabinet door, operating handles and spare parts specified in the contract.
  • 商务咨询 E-MAIL:123569338@qq.com
  • 热线电话 TEL:0577-27892288
CN

TEL

Contact number

0086-0577-27892288

Contact fax

0086-0577-27892287

WeChat

二维码

Scan WeChat

E-MAIL

E-mail

123569338@qq.com